Engineering & Design Build

At North East Fire Protection Systems, Inc. our team of experienced designers utilizes, AutoCAD, HydraCAD, Hydralist and HydraCalc technologies to design our projects. North East Fire Protection provides hydrant flow tests, as well as annual hydrant inspections per NFPA-25. We provide this service for ITM as well as engineering and planning purposes. Call us today to get a quote.

 

Active Fire Protection Design Team Combined Experience

  • Combined "in-house" active fire protection design experience of over 100 years
  • State of Vermont Certification TQP
  • Designed systems in New York and Massachusetts, as well as Vermont
  • NICET Certified
  • Experience working within the guidelines set by owners insurance companies such as FM Global 
  • Experience coordinating with other trades
  • Design build
  • Specified bid work

Experienced with Active Fire Protection Type Systems

  • Wet Systems
  • Dry Systems
  • Pre-Action (single and double interlock)
  • Deluge Systems
  • Foam Systems

Type of Projects 

  • Hospitals
  • Hotels
  • Houses
  • Inns
  • Condominiums
  • Multiple Military Bases
  • Multiple Ski Lodges
  • Mercantile Strip Stores and Malls
  • Restaurants
  • Baseball and Softball Training Facilities
  • Gyms and Multiple YMCA Facilities
  • Multiple new and occupied Nursery Schools, Grade Schools, and Colleges
  • Paper Mills and Printing Complexes
  • Computer Rooms
  • Multiple new and occupied Nursing Homes
  • Trucking and Storage Facilities
  • Freezer Buildings
  • Paint Facilities
  • Multiple Box Stores
  • Portable Buildings and Props
  • Banks
  • MRI and Cat Scan Rooms
  • Multiple Production Facilities
  • Dance Studios
  • Town Halls and Courthouses
  • Multiple Pharmacies
  • Multiple Grocery Stores
  • IBM, GE, and KAPL Facilities
  • Taverns
  • Multiple Worship Centers and Recreation/Meeting Facilities 
  • Tire Storage
  • Chemical Storage
  • Paper Storage
  • Barns

Experienced with the following Construction Methods

  • New construction and Retrofit construction
  • Conventional wood
  • Post and beam
  • TGI and laminated beam
  • Open wood truss
  • Poured concrete
  • Spancrete (precast concrete)
  • Tip up (pour in place concrete)
  • Post tensioned concrete
  • Concrete T
  • Conventional steel
  • Prefabricated buildings

Experienced with the following Standards

  • NFPA 11 Standard for Low, Medium, and High Expansion Foam
  • NFPA 13D Standard for the Installation of Sprinkler Systems in One and Two Family Dwellings
  • NFPA 13R Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies
  • NFPA 13 Standard for the Installation of Sprinkler Systems
  • NFPA 14 Standard for the Installation of Standpipe and Hose System
  • NFPA 20 Standard for the Installation of Stationary Pumps for Fire Protection
  • NFPA 22 Standard for Water Tanks for Private Fire Protection Systems
  • NFPA 25 Standard for the Inspection, Testing, and Maintenance of Water Based Fire Protection Systems
  • NFPA 33 Standard for Spray Application Using Flammable or Combustible Materials
  • NFPA 101 Life Safety Code
  • NFPA 409 Standard on Aircraft Hangers